Sea water cooling pump: no pressure and low current after overhaul

Pumps

Contents
  1. Symptoms
  2. Checked
  3. Diagnosis
  4. Fix
  5. Comments · 0

Symptoms#

  • The cooling sea water pump had just been overhauled, and a new motor was fitted: 25.3 kW, 39.5 A, 440 V delta, 1800 rpm.
  • After start the pump gave no pressure.
  • Motor current rose from 17 A to 24 A and stayed at 24 A. The nameplate says 39.5 A.

Checked#

CheckResult
Motor connectionDelta, as on the nameplate
Pump valvesAll open
SW pressure on the alarm system (Aconis), one other pump running1.6 bar
Start this pump as wellPressure did not change
Start another good pump insteadPressure rose to 2.6 bar

Diagnosis#

The fault was in the pump, not in the motor. During the overhaul the impeller had been fitted the wrong way round. The pump moved almost no water, so the motor ran at low load and the current stayed far below the nameplate value.

Fix#

Refitted the impeller the right way round.