Sea water cooling pump: no pressure and low current after overhaul
EL-0001 · Solved · rating 0 · works for 0 engineers · occurred 03 Jun 2019
Source: /cases/el-0001
Symptoms#
- The cooling sea water pump had just been overhauled, and a new motor was fitted: 25.3 kW, 39.5 A, 440 V delta, 1800 rpm.
- After start the pump gave no pressure.
- Motor current rose from 17 A to 24 A and stayed at 24 A. The nameplate says 39.5 A.
Checked#
| Check | Result |
|---|---|
| Motor connection | Delta, as on the nameplate |
| Pump valves | All open |
| SW pressure on the alarm system (Aconis), one other pump running | 1.6 bar |
| Start this pump as well | Pressure did not change |
| Start another good pump instead | Pressure rose to 2.6 bar |
Diagnosis#
The fault was in the pump, not in the motor. During the overhaul the impeller had been fitted the wrong way round. The pump moved almost no water, so the motor ran at low load and the current stayed far below the nameplate value.
Fix#
Refitted the impeller the right way round.