Someone has already fixed it on another ship.
Real cases from engine rooms: the symptom, what was measured, what it turned out to be and what fixed it. Written by engineers, confirmed by the ones it worked for.
197 cases35 engineers8 886 documents in the library
Top fixes this month
1 rating0 commentsConsilium CS4000: "IOM70 Synchronisation signal" faultFault alarm on the water mist main panel: "(212) CENTRAL 1 IOM70 51 SYNCHRONISATION SIGNAL", with "PUMP CONTROL BOX - UNIT FAULT INPUTS". On the I/O M70 module: PS LED flashing yellow, COM LED green.…Anonymous · 6 mo1 rating0 commentsHyundai HV switchboard: generator VCB tripped, no reset buttonThe generator engine shut down on lube oil. HIMAP showed reverse power, and the generator VCB (6600 V) tripped. The breaker could not be reset at the breaker. There is no reset button and no handle…Anonymous · 7 mo1 rating0 commentsPropeller shaft earthing device: what it does and why it mattersA colleague asked me what a shaft earthing device does and why it is important. I work on ships, and this is how I explain it. Why the device is needed When the shafting turns, the propeller,…Anonymous · 3 y0 rating0 commentsEngine room fire: fuel backflow through an open return line (Scot Stuttgart)Chemical tanker with two engine rooms, alongside in San Juan discharging cargo. The port AE was under LOTO for turbocharger and aftercooler cleaning. The crew removed the aftercooler and the fuel…Anonymous · 2 mo0 rating0 commentsSwitchboard earth lamps do not light, only one of three on lamp testThe insulation resistance monitor (IRM) worked normally. The earth lamps did not light. With the test button pressed, only one of the three lamps lit.Anonymous · 3 mo
Latest cases
All, newest first →0 rating0 commentsEngine room fire: fuel backflow through an open return line (Scot Stuttgart)Chemical tanker with two engine rooms, alongside in San Juan discharging cargo. The port AE was under LOTO for turbocharger and aftercooler cleaning. The crew removed the aftercooler and the fuel…Anonymous · 2 mo0 rating0 commentsSwitchboard earth lamps do not light, only one of three on lamp testThe insulation resistance monitor (IRM) worked normally. The earth lamps did not light. With the test button pressed, only one of the three lamps lit.Anonymous · 3 mo0 rating0 commentsHi Air Korea AC: compressor will not start, "FRESH ARM 1CRUN"The AC compressor did not start. No alarms were showing. When starting the compressor, only the controller on the AC control panel showed a new alarm: FRESH ARM 1CRUN. The manuals do not explain this…Anonymous · 4 mo1 rating0 commentsConsilium CS4000: "IOM70 Synchronisation signal" faultFault alarm on the water mist main panel: "(212) CENTRAL 1 IOM70 51 SYNCHRONISATION SIGNAL", with "PUMP CONTROL BOX - UNIT FAULT INPUTS". On the I/O M70 module: PS LED flashing yellow, COM LED green.…Anonymous · 6 mo0 rating0 commentsGenerator engine fails on non-OEM bearings run to OEM intervals (Kommandor Susan)Diesel-electric vessel on sea trials, just out of the lock at Leith with a pilot on board. DG1 and DG4 were on line. The C/E heard a change in engine note on one generator, then a loud bang. The fire…Anonymous · 6 mo
Browse by equipment
How it works
- 01Find the caseSearch by alarm code, maker or symptom, in any language. Each case shows what was measured, the cause and the fix.
- 02Fix and confirmWhen it works on your ship, press “Worked for me”. The fixes that work most often rise to the top.
- 03Write yoursKeep notes private in your logbook, or publish them and help the next engineer at 3 a.m.