Yanmar generator: low LO pressure shutdown 5 minutes after start
EL-0008 · Solved · rating 0 · works for 0 engineers · occurred 19 Feb 2022
Source: /cases/el-0008
Symptoms#
- After start, LO pressure was normal (4.8 bar), then slowly fell.
- After 5–6 minutes at most, the engine shut down on low LO pressure.
- The differential pressure indicator on the automatic LO filter showed red while running. After stopping it went back to white.
- Oil temperature was about 48 °C. The shutdown came before 50 °C.
Checked#
| Check | Result |
|---|---|
| Filter candles | Removed many times, clean; new candles fitted |
| Auto filter housing and impeller | Dismantled; turns freely, drive engages |
| LO thermostat | Swapped with one from another generator — no change |
| Pressure regulating valve | Adjusted — no change |
Diagnosis#
The new filter candles had a finer mesh than the old ones. They looked the same, but did not pass enough oil. Compare the mesh marking on new candles with the ones that were fitted before.
Fix#
- Cleaned the old filter candles well.
- Replaced every second new candle with a cleaned old one. Ran the engine — pressure stayed normal.
- Fitted all the old candles. Ran the engine under load.
Result#
So far, LO pressure stays normal under load.