MAN 6S50ME-B: high exhaust temperature on all cylinders at part load
EL-0020 · Solved · rating 0 · works for 0 engineers · occurred 10 Jun 2024
Source: /cases/el-0020
Symptoms#
- At 82–85 rpm (about 55% load; normal sea speed is 90 rpm), exhaust temperature rose on all six cylinders.
- Exhaust outlet temperatures were 416–437 °C, mean 427 °C. At sea trial this was about 340 °C.
- Scavenge air pressure was low: 1.22–1.24 bar.
- All cylinders were equal. Other parameters were close to sea trial values.
- A bypass valve alarm was standing on the MOP.
Checked#
| Check | Result |
|---|---|
| Indicator diagrams (PMI) | All cylinders equal, normal |
| HPS hydraulic oil pressure | 239–241 bar (normally 250 bar) — not the cause |
| Exhaust gas boiler | Washed a month before, pressure drop normal |
| MOP > Auxiliaries > Scavenge Air | Bypass mode Auto, set point 100%, opening 100% |
| Bypass valve on site | Fully open |
Diagnosis#
The turbocharger exhaust gas bypass valve stayed fully open. Part of the exhaust gas went past the turbine. Turbocharger speed and scavenge air pressure dropped, so exhaust temperatures went up.
The valve is driven by a Siemens electro-pneumatic positioner. Its display worked, but it gave no air to the actuator. In manual mode it did not respond.
Fix#
- Closed the bypass valve by hand as a temporary measure.
- The positioner is to be removed and checked in port. If faulty, replace its pneumatic block or the whole positioner.
Comments · 0