Log inJoin

Boiler feed pumps air-lock every few hours and trip on low pressure

BoilerPumps

Contents
  1. Symptoms
  2. Checked
  3. Diagnosis
  4. Fix
  5. Result
  6. Comments · 0

Symptoms#

  • Boiler feed water pumps get air-locked. After venting they run for 2–3 hours (sometimes up to 2 days), then the same again.
  • Both pump motors trip. Low pressure alarms on the boiler panel, mostly at each boiler top-up.
  • Discharge valves of both pumps are open to the common line. This was always so and gave no problem before.
  • Bubbles formed under the pump casing, and the feed line became very hot.

Checked#

CheckResult
Hot well temperature85 °C
Non-return valves, first checkLooked OK
Chemical dosing valves to the feed linePassing (full tank emptied overnight), not the main cause

Diagnosis#

The non-return valves did not hold — both after the pumps and from the boiler. Hot water and steam from the boiler came back into the feed line, and the pumps steam-locked. The hot line and the bubbles at the pump casing were the clear signs.

Fix#

  1. Changed over to the other feed line.
  2. Lapped the non-return valves.

Result#

24 hours with no alarms.