Boiler feed pumps air-lock every few hours and trip on low pressure
EL-0028 · Solved · rating 0 · works for 0 engineers · occurred 11 Aug 2025
Source: /cases/el-0028
Symptoms#
- Boiler feed water pumps get air-locked. After venting they run for 2–3 hours (sometimes up to 2 days), then the same again.
- Both pump motors trip. Low pressure alarms on the boiler panel, mostly at each boiler top-up.
- Discharge valves of both pumps are open to the common line. This was always so and gave no problem before.
- Bubbles formed under the pump casing, and the feed line became very hot.
Checked#
| Check | Result |
|---|---|
| Hot well temperature | 85 °C |
| Non-return valves, first check | Looked OK |
| Chemical dosing valves to the feed line | Passing (full tank emptied overnight), not the main cause |
Diagnosis#
The non-return valves did not hold — both after the pumps and from the boiler. Hot water and steam from the boiler came back into the feed line, and the pumps steam-locked. The hot line and the bubbles at the pump casing were the clear signs.
Fix#
- Changed over to the other feed line.
- Lapped the non-return valves.
Result#
24 hours with no alarms.