Log inJoin

Carrier reefer container: Alarm 15 "Loss of cooling", no ice on evaporator

Refrigeration & HVACCarrier StreamlineAlarm 15 Loss of cooling

Contents
  1. Symptoms
  2. Checked
  3. Diagnosis
  4. Fix
  5. Result
  6. Comments · 0

Symptoms#

  • Reefer container found with Alarm 15 "Loss of cooling".
  • It felt like something was blocking the air flow.
  • When warm water was poured over the evaporator, nothing came out of the drain tube.

Checked#

CheckResult
Evaporator coilNo ice
Evaporator fansTurn in the correct direction
Suction / discharge pressure0.7 / 11.2 bar
Suction temperature−26 °C

Diagnosis#

The air duct was frozen solid, right down to the bottom. Ice blocked the air flow.

Fix#

  1. Warmed up the cover of the supply air sensors.
  2. Poured water in there to clear the ice.

Result#

The unit started cooling again.

Comments · 0

No comments yet.

Sign in to comment, vote and confirm fixes.Sign in