SEA-Mate B500 blender stops after blending, blend not discharged
EL-0062 · Solved · rating 0 · works for 0 engineers · occurred 11 Sept 2023
Source: /cases/el-0062
Symptoms#
- In auto mode the unit mixes the oils, then stops and stays stopped.
- It should open the valve and pump the blend on, but it does not.
- No alarm.
Diagnosis#
- Every month the unit asks for a test of the high-high level alarm: you pull a lever to lift the float.
- At the last test the lever was pulled too hard. The rod came out about 10 cm instead of the normal 2–3 cm.
- Inside, a thin metal fork was bent flat. The fork also broke a piece off the float (the float is made of a foam-type material).
- The broken float hung in a wrong, in-between position. It gave no alarm, but the program left out the oil discharge cycle.
Comments · 0