Alfa Laval 856 separator: "Bowl leak" alarm during the leakage test
EL-0066 · Solved · rating 0 · works for 0 engineers · occurred 15 Feb 2024
Source: /cases/el-0066
Symptoms#
- "Bowl leak" alarm, but only during the test steps TI 66 or TI 71 (leakage test on fuel).
- Most often when displacement water was fed.
- During TI 66 the pressure fell from 1.6 to about 0.4 bar in about 3 seconds.
- During TI 77 the PT4 pressure did not rise.
Checked#
| Check | Result |
|---|---|
| Water and air solenoid valve blocks | Replaced — no change |
| Separator | Cleaned and overhauled — no change |
| Fuel outlet valve V4 | Replaced — no change |
| Separated water discharge valve | Holds — OK |
Diagnosis#
An air hose on the solenoid valve block had come slightly loose and was leaking.
The block body is a casting with very small holes (about 1 mm) where the air hoses screw in. So the air flow to each valve is very small. Even this small leak was enough to stop valve V4 (fuel outlet) from closing during the test.
Fix#
Tightened the air hose connection on the solenoid valve block.
Result#
Problem solved.