Log inJoin

Alfa Laval 856 separator: "Bowl leak" alarm during the leakage test

PurifierAlfa Laval 856Bowl leak

Contents
  1. Symptoms
  2. Checked
  3. Diagnosis
  4. Fix
  5. Result
  6. Comments · 0

Symptoms#

  • "Bowl leak" alarm, but only during the test steps TI 66 or TI 71 (leakage test on fuel).
  • Most often when displacement water was fed.
  • During TI 66 the pressure fell from 1.6 to about 0.4 bar in about 3 seconds.
  • During TI 77 the PT4 pressure did not rise.

Checked#

CheckResult
Water and air solenoid valve blocksReplaced — no change
SeparatorCleaned and overhauled — no change
Fuel outlet valve V4Replaced — no change
Separated water discharge valveHolds — OK

Diagnosis#

An air hose on the solenoid valve block had come slightly loose and was leaking.

The block body is a casting with very small holes (about 1 mm) where the air hoses screw in. So the air flow to each valve is very small. Even this small leak was enough to stop valve V4 (fuel outlet) from closing during the test.

Fix#

Tightened the air hose connection on the solenoid valve block.

Result#

Problem solved.