WinGD DF engine: running on VLSFO with a seized pilot fuel pump

Main EngineWinGD DF

Notes#

The pilot fuel pump seized. The question was how long the engine can run without it before the pilot injector nozzle holes coke up.

  • The engine ran on VLSFO for 10 days with no pilot fuel supply.
  • When the new pump arrived, the pilot injectors were not coked.
  • After the new pump was fitted, the engine ran normally on gas.

Running on gas#

In gas mode the main fuel injectors are not used. Once a week, change over to the main injectors for 1–2 hours so that their nozzle holes do not coke.