Thruster start dips the ship's voltage, breaker trips, lights flicker
EL-0099 · Solved · rating 0 · works for 0 engineers · occurred 20 Jun 2020
Source: /cases/el-0099
Symptoms#
- Each time the thruster was started, the ship's voltage dipped.
- Sometimes the breaker tripped. Other times the lights on board only flickered.
- Even the radar switched off.
Checked#
The thruster motor has an autotransformer starter. Several single-core cables enter the motor: some from the autotransformer and some from the switchboard.
A megger was connected, and each cable was shaken by hand while watching the reading. This found the faulty cable.
Diagnosis#
One cable had chafed through against the floor plates. The damage was not visible. When the thruster ran up, vibration made this phase short to the hull.
This was the cause of the voltage dips and the breaker trips.
Comments · 0
No comments yet.