Log inJoin

Scania generator (DEC2): fires 2 or 3 times at start, then fuel is cut off

Auxiliary EngineScania, DEC2 digital engine control

Contents
  1. Symptoms
  2. Checked
  3. Diagnosis
  4. Fix
  5. Result
  6. Comments · 0

Symptoms#

  • The diesel generator cranks and fires 2–3 times, as if trying to start.
  • Then the fuel supply stops and the engine does not start.
  • Fuel comes back only after the DEC2 digital engine control system switches off.
  • No overspeed alarm.

Checked#

CheckResult
Oil pressure switchClosed at standstill, opens when the engine starts — OK
Low oil pressure / high coolant temperature shutdownsDisabled with the DIP switch in the DEC2 unit — still no start

Diagnosis#

The DEC2 digital engine control unit was faulty.

Fix#

Fitted a new DEC2 control unit.

The new Scania DEC2 control unit fitted on the generator
The new Scania DEC2 control unit fitted on the generator

Result#

The generator started at once.

Comments · 0

No comments yet.