Log inJoin

Steering gear pump motor gets voltage but does not turn or hum

Steering GearElectrical

Contents
  1. Symptoms
  2. Diagnosis
  3. Fix
  4. Result
  5. Comments · 0

Symptoms#

  • The steering gear pump motor did not start. It did not turn and did not even hum.
  • Voltage was present between phases at the motor terminal box.

Diagnosis#

The motor is started star-delta. Starter contactors: 88 (main), 6 (star), 42 (delta).

Only 88 closed; 6 and 42 stayed open. Voltage came to the winding starts, but the winding ends were not connected in star or in delta. So there was no current and no rotation.

Motor terminal box: six leads, no links; star and delta are made by the contactors in the starter
Motor terminal box: six leads, no links; star and delta are made by the contactors in the starter

The cause was the star-delta timer relay T1. Inside it, the wire end from the control power transformer had burnt off.

Fix#

  1. Repaired the burnt wire end inside T1 as a temporary repair (the part is very small).
  2. Ordered a new timer relay.

Result#

The steering gear started. Normal sequence: 88 and 6 close (star); after the time delay, 6 opens and 42 closes (delta); 88 stays closed.

Comments · 0

No comments yet.

Sign in to comment, vote and confirm fixes.Sign in