Sauer air-cooled service air compressor overheats (105 °C)
EL-0017 · Solved · rating 0 · works for 0 engineers · occurred 16 Feb 2024
Source: /cases/el-0017
Symptoms#
- The air-cooled service air compressor overheated. The controller showed 105 °C at 5.6 bar.
Checked#
| Check | Result |
|---|---|
| Compressor oil | Changed — no change |
| Filters | Clean |
| Compartment doors | Closed |
| Extra fans on the air suction side | Fitted — still overheating |
Diagnosis#
The oil thermostat had failed. It sends oil through the cooler or around it (small circuit). When it fails, the oil goes around the cooler.
The manual shows a separate thermostat, but this compressor has none. The thermostat is built inside the compressor: look in the block that the oil separator screws onto.
Fix#
- Replaced the thermostat stem — no effect.
- Took the thermostat out and fitted a blank plug in its place, so all oil goes through the cooler.
- Ordered a new thermostat.
Result#
Oil temperature stays at about 75 °C under load and does not go higher.