Sauer air-cooled service air compressor overheats (105 °C)

Compressed AirSauer Compressors, Air Control 1 controller

Contents
  1. Symptoms
  2. Checked
  3. Diagnosis
  4. Fix
  5. Result
  6. Comments · 0

Symptoms#

  • The air-cooled service air compressor overheated. The controller showed 105 °C at 5.6 bar.
Air Control 1 display: 5.6 bar and 105 °C
Air Control 1 display: 5.6 bar and 105 °C

Checked#

CheckResult
Compressor oilChanged — no change
FiltersClean
Compartment doorsClosed
Extra fans on the air suction sideFitted — still overheating

Diagnosis#

The oil thermostat had failed. It sends oil through the cooler or around it (small circuit). When it fails, the oil goes around the cooler.

The manual shows a separate thermostat, but this compressor has none. The thermostat is built inside the compressor: look in the block that the oil separator screws onto.

Fix#

  1. Replaced the thermostat stem — no effect.
  2. Took the thermostat out and fitted a blank plug in its place, so all oil goes through the cooler.
  3. Ordered a new thermostat.

Result#

Oil temperature stays at about 75 °C under load and does not go higher.