TMC Tamrotor screw compressor: "R:3137 RUN INHIBIT", "check pressure in pipe"
EL-0080 · Solved · rating 0 · works for 0 engineers · occurred 12 Mar 2025
Source: /cases/el-0080
Symptoms#
- The display showed 6.0 bar and "R:3137 RUN INHIBIT".
- The manual has only two alarms marked R. For them it says: "check pressure in pipe".
Diagnosis#
- A solenoid valve had seized (corroded).
- The small pipe to this solenoid valve was half blocked.
Comments · 0