Alfa Laval SA820: "Sludge in bowl" alarm every day or two after overhaul
EL-0042 · Solved · rating 0 · works for 0 engineers · occurred 13 Aug 2021
Source: /cases/el-0042
Contents
Symptoms#
- After an overhaul the separator ran normally for several days.
- Then the "Sludge in bowl" alarm came every one or two days.
- The separator had tried to calibrate itself and could not close the bowl.
Diagnosis#
- During the overhaul the orifice on the bowl closing valve was found dirty and was replaced.
- The new, clean orifice lets more water through. With the old closing time, the closing water closed the bowl and then opened it again at once.
- So the closing timer Ti64 was set shorter. This worked in normal operation.
- Timer Ti75 checks the separator parameters. If one goes out of range after calibration, it starts an automatic calibration.
- The calibration uses its own bowl closing time, Ti58. Ti58 was not changed.
- Ti58 and Ti64 do the same job but had different times. So during the automatic calibration the bowl could not close.
Fix#
Set Ti58 to the same closing time as Ti64.