Alfa Laval SA820: "Sludge in bowl" alarm every day or two after overhaul

PurifierAlfa Laval SA820Sludge in bowl

Contents
  1. Symptoms
  2. Diagnosis
  3. Fix
  4. Comments · 0

Symptoms#

  • After an overhaul the separator ran normally for several days.
  • Then the "Sludge in bowl" alarm came every one or two days.
  • The separator had tried to calibrate itself and could not close the bowl.

Diagnosis#

  • During the overhaul the orifice on the bowl closing valve was found dirty and was replaced.
  • The new, clean orifice lets more water through. With the old closing time, the closing water closed the bowl and then opened it again at once.
  • So the closing timer Ti64 was set shorter. This worked in normal operation.
  • Timer Ti75 checks the separator parameters. If one goes out of range after calibration, it starts an automatic calibration.
  • The calibration uses its own bowl closing time, Ti58. Ti58 was not changed.
  • Ti58 and Ti64 do the same job but had different times. So during the automatic calibration the bowl could not close.

Fix#

Set Ti58 to the same closing time as Ti64.