0 rating0 commentsKongsberg K-Chief 600: "ME SBW pot.meter" alarm after lever calibrationTroubleshootingMain Engine · Kongsberg K-Chief 600 · ME SBW POT.METERThe telegraph lever on the starboard bridge wing was calibrated. The calibration went normally. At the next manoeuvring the alarm "Lock in Last 'Speed Set Bridge'" came. It cleared. The alarm "ME SBW…Anonymous · 2 y0 rating0 commentsShaft torque meters with strain gauges: calibrate every 6 monthsKnowledgePropulsion & ThrustersI recommend calibrating shaft torque meters (shaft power meters) on the propulsion shafting every 6 months, at least those with strain gauges, because regular calibration stops the strain-gauge…Anonymous · 4 y0 rating0 commentsAlfa Laval SA820: "Sludge in bowl" alarm every day or two after overhaulTroubleshootingPurifier · Alfa Laval SA820 · Sludge in bowlAfter an overhaul the separator ran normally for several days. Then the "Sludge in bowl" alarm came every one or two days. The separator had tried to calibrate itself and could not close the bowl.Anonymous · 5 y0 rating0 commentsDamcos slop valve shows 67 % when closedTroubleshootingAutomation / PLC · DamcosCargo (slop) valve that can be opened by percent. At 100 % open, the monitor and the local indicator agree. With the valve actually closed, the indicator shows 67 %. When opened to 80 %, the valve…Anonymous · 2 y0 rating0 commentsTanker fixed gas sampling system: monthly and yearly checksKnowledgeFire & SafetyThe fixed gas sampling system on an oil tanker needs monthly crew checks (visual inspection, alarm test, zero and span calibration) plus, as good practice, a yearly health check by an authorized…Anonymous · 4 y0 rating0 commentsInert gas oxygen analyzers keep failing: a care routine that worksProcedureFire & SafetyInert gas (IG) oxygen analyzers that fail again and again are, in my view, usually handled badly or not maintained correctly; this is the care routine I use to prevent it. Repeated failures with…Anonymous · 4 y0 rating0 commentsMain engine liners: how often to do external wear scanningKnowledgeMain EngineExternal electronic scanning of main engine cylinder liners by an outside company is worth doing; what is not settled is how often, at least yearly or about every 5 years backed by onboard…Anonymous · 4 y0 rating0 commentsMacGregor crane: alarm 93 "Encoder wrong position", crane stopsTroubleshootingDeck Machinery · MacGregor · 93 Encoder wrong positionAlarm 93 "Encoder wrong position" on the hoisting and luffing MPC. After one MPC was replaced, the alarm still came, but the crane could be operated. An hour later the alarm came again and the crane…Anonymous · 4 y0 rating0 commentsDoppler speed log: water track vs bottom trackKnowledgeNavigationWater track and bottom track on a Doppler speed log use the same Doppler principle; the only difference is the surface that reflects the signal. This note covers how the log works in each mode.…Anonymous · 1 y0 rating0 commentsSOx scrubber failure: what to do to stay compliant (MEPC.1/Circ.883)ProcedureOtherWhen the exhaust gas cleaning system (EGCS, SOx scrubber) fails and no longer meets the scrubber guidelines, I follow IMO MEPC.1/Circ.883, which covers EGCS malfunctions. This procedure sets out the…Anonymous · 4 y