Log inJoin

Furuno FAR-2837S radar: antenna motor thermal overload trips at switch-on

NavigationFuruno FAR-2837S (S-band)

Contents
  1. Symptoms
  2. Diagnosis
  3. Fix
  4. Result
  5. Comments · 0

Symptoms#

  • S-band radar. The antenna is turned by an AC motor-gearbox, 3-phase 220 V, without brushes.
  • The motor wires go straight into the motor body, there is no terminal box.
  • As soon as the antenna is switched on, the motor thermal overload trips.

Diagnosis#

The soft-start PCB in the antenna unit had failed. This board feeds the motor. It is behind the cover on the opposite side from the motor.

Fix#

Bypassed one of the phases on the soft-start PCB. A new soft-start PCB is the permanent fix.

Result#

The antenna turns and the thermal overload no longer trips.

With the soft start bypassed, each start is harder on the gearbox. Keep starts and stops to a minimum: better to leave the antenna turning.

Comments · 0

No comments yet.

Sign in to comment, vote and confirm fixes.Sign in