Furuno FAR-2837S radar: antenna motor thermal overload trips at switch-on
EL-0043 · Solved · rating 0 · works for 0 engineers · occurred 10 Sept 2021
Source: /cases/el-0043
Symptoms#
- S-band radar. The antenna is turned by an AC motor-gearbox, 3-phase 220 V, without brushes.
- The motor wires go straight into the motor body, there is no terminal box.
- As soon as the antenna is switched on, the motor thermal overload trips.
Diagnosis#
The soft-start PCB in the antenna unit had failed. This board feeds the motor. It is behind the cover on the opposite side from the motor.
Fix#
Bypassed one of the phases on the soft-start PCB. A new soft-start PCB is the permanent fix.
Result#
The antenna turns and the thermal overload no longer trips.
With the soft start bypassed, each start is harder on the gearbox. Keep starts and stops to a minimum: better to leave the antenna turning.
Comments · 0