Westfalia OSD 18: weak sludge discharge when hydrophore pressure is low
EL-0048 · Solved · rating 0 · works for 0 engineers · occurred 10 Jan 2022
Source: /cases/el-0048
Symptoms#
- Poor sludge discharge: no normal "bang", the bowl only "sneezes" and little comes out.
- Everything else worked correctly.
- With the hydrophore at 5.1–5.6 bar the discharge was normal. At 4.3 bar the pressure was not enough.
Checked#
The separator had been fully overhauled and the parts renewed. No change.
Fix#
Increased the operating water (discharge) impulse time in the settings:
| Setting | Before (as per manual) | After |
|---|---|---|
| Operating water impulse for discharge | 2 s | 3 s |
Increase it in small steps (for example 2.5 s first). Check that the discharge is not too violent when the hydrophore pressure is at its highest (5.6 bar).
Result#
With 3 s the separator discharges normally.