Westfalia OSD 18: weak sludge discharge when hydrophore pressure is low

PurifierWestfalia OSD 18

Contents
  1. Symptoms
  2. Checked
  3. Fix
  4. Result
  5. Comments · 0

Symptoms#

  • Poor sludge discharge: no normal "bang", the bowl only "sneezes" and little comes out.
  • Everything else worked correctly.
  • With the hydrophore at 5.1–5.6 bar the discharge was normal. At 4.3 bar the pressure was not enough.

Checked#

The separator had been fully overhauled and the parts renewed. No change.

Fix#

Increased the operating water (discharge) impulse time in the settings:

SettingBefore (as per manual)After
Operating water impulse for discharge2 s3 s

Increase it in small steps (for example 2.5 s first). Check that the discharge is not too violent when the hydrophore pressure is at its highest (5.6 bar).

Result#

With 3 s the separator discharges normally.