Westfalia OSD 60-91: bowl does not close, ejection monitoring alarm
EL-0022 · Solved · rating 0 · works for 0 engineers · occurred 23 Jul 2024
Source: /cases/el-0022
Symptoms#
- Two main engine LO separators stopped one after the other on the ejection monitoring alarm.
- On both, the bowl did not close at all. No discharge either, not even a small one.
- No. 1 stopped 1,000 hours after its 8,000-hour maintenance. No. 2 had just been overhauled.
Checked#
| Check | Result |
|---|---|
| Operating water pressure | 8 bar, drops to 4.2–4.3 bar when the valve opens |
| Water pipes disconnected | Water flows (quantity not measured) |
| Solenoid valves | Open as per program; manual discharge also tried — no effect |
| Solenoid valve filter | Cleaned |
| Brake shoes | Within limits |
| Belt | Replaced about 3 weeks before |
| Motor current | About 50 A at start, 13 A after the run-up timer |
| Other separators on the same water supply | No problems |
Diagnosis#
The operating water pipe (carbon steel) to the separator did not pass enough water. The gauge pressure looked normal, but the water quantity was too low to close the bowl.
Fix#
Flushed the operating water pipe to the separator.
Result#
Separator No. 1 started and worked normally after flushing.