Westfalia OSD 60-91: bowl does not close, ejection monitoring alarm

PurifierWestfalia OSD 60-91Ejection monitoring

Contents
  1. Symptoms
  2. Checked
  3. Diagnosis
  4. Fix
  5. Result
  6. Comments · 0

Symptoms#

  • Two main engine LO separators stopped one after the other on the ejection monitoring alarm.
  • On both, the bowl did not close at all. No discharge either, not even a small one.
  • No. 1 stopped 1,000 hours after its 8,000-hour maintenance. No. 2 had just been overhauled.

Checked#

CheckResult
Operating water pressure8 bar, drops to 4.2–4.3 bar when the valve opens
Water pipes disconnectedWater flows (quantity not measured)
Solenoid valvesOpen as per program; manual discharge also tried — no effect
Solenoid valve filterCleaned
Brake shoesWithin limits
BeltReplaced about 3 weeks before
Motor currentAbout 50 A at start, 13 A after the run-up timer
Other separators on the same water supplyNo problems

Diagnosis#

The operating water pipe (carbon steel) to the separator did not pass enough water. The gauge pressure looked normal, but the water quantity was too low to close the bowl.

Fix#

Flushed the operating water pipe to the separator.

Result#

Separator No. 1 started and worked normally after flushing.