Kongsberg K-Chief 600: "ME SBW pot.meter" alarm after lever calibration
EL-0064 · Solved · rating 0 · works for 0 engineers · occurred 06 Jan 2024
Source: /cases/el-0064
Symptoms#
- The telegraph lever on the starboard bridge wing was calibrated. The calibration went normally.
- At the next manoeuvring the alarm "Lock in Last 'Speed Set Bridge'" came. It cleared.
- The alarm "ME SBW POT.METER" stayed, with status IFH and a value of 0.6–0.8 %. The port wing lever showed the same value with no alarm.
- The main engine would not start ahead from the starboard wing. It did start astern.
Checked#
- In calibration mode the lever at STOP (0) showed 100 % (Navig. Full). With the lever at Full it also showed 100 %.
Fix#
- Reset the starboard wing lever potentiometer on the CAN bus.
- Calibrated the lever again.
Result#
The main engine runs ahead from the starboard wing.
Comments · 0
No comments yet.