Log inJoin

Kongsberg K-Chief 600: "ME SBW pot.meter" alarm after lever calibration

Main EngineAutomation / PLCKongsberg K-Chief 600ME SBW POT.METER

Contents
  1. Symptoms
  2. Checked
  3. Fix
  4. Result
  5. Comments · 0

Symptoms#

  • The telegraph lever on the starboard bridge wing was calibrated. The calibration went normally.
  • At the next manoeuvring the alarm "Lock in Last 'Speed Set Bridge'" came. It cleared.
  • The alarm "ME SBW POT.METER" stayed, with status IFH and a value of 0.6–0.8 %. The port wing lever showed the same value with no alarm.
  • The main engine would not start ahead from the starboard wing. It did start astern.
Alarm "ME SBW POT.METER", 0.8 %, IFH
Alarm "ME SBW POT.METER", 0.8 %, IFH
Alarm list: "Lock in Last 'Speed Set Bridge'"
Alarm list: "Lock in Last 'Speed Set Bridge'"

Checked#

  • In calibration mode the lever at STOP (0) showed 100 % (Navig. Full). With the lever at Full it also showed 100 %.

Fix#

  1. Reset the starboard wing lever potentiometer on the CAN bus.
  2. Calibrated the lever again.

Result#

The main engine runs ahead from the starboard wing.

Comments · 0

No comments yet.