Alfa Laval P615 oil purifier: bowl does not close, PT4 0.00

PurifierAlfa Laval P615PT4 high at discharge

Contents
  1. Symptoms
  2. Checked
  3. Fix
  4. Result
  5. Comments · 0

Symptoms#

  • The bowl did not close for a week. PT4 showed 0.00.
  • A manual discharge gave the alarm "PT4 high at discharge".

Checked#

CheckResult
Rubber sealsReplaced — no change
Solenoid valve blockOK
ShaftOK
HosesOK
Orifices on the water block (all 3)OK

Fix#

  1. Removed the motor.
  2. Checked the friction pads of the coupling.
  3. Fitted the same pads back and put the motor back in place.

Result#

The bowl closed and the purifier worked again. No part was replaced: removing and refitting the motor and the friction pads was enough.