Main engine: fuel pressure slowdowns, deaeration chamber full of gas
EL-0109 · Solved · rating 0 · works for 0 engineers · occurred 26 May 2021
Source: /cases/el-0109
Symptoms#
- Repeated main engine slowdowns on fuel oil pressure. It took about 4 days to find the cause.
- The deaeration chamber was "boiling" with gas.
- The gas came into the fuel system through the return line of unit 4.
Checked#
| Check | Result |
|---|---|
| Fuel injection graphs | Normal on all units |
| Exhaust temperatures | Equal on all units |
Diagnosis#
The fuel valve (injector) of unit 4 was cracked. Combustion gas went through the crack into the fuel side and out through the return line. Firing pressure (about 140 bar) is much higher than the fuel pressure inside the valve between injections (about 7–8 bar), so the gas is pushed into the fuel.
Normal injection graphs and equal temperatures did not show this fault.
Fix#
Replaced the cracked fuel valve on unit 4.
Comments · 0