OWS 15 ppm monitor cannot detect a blocked sampling line

OWS & BilgeJOWA; Bilgemon488 15 ppm monitor

Notes#

A 15 ppm bilge alarm without a low sample flow switch cannot tell when its sampling line is closed or blocked, so the OWS can keep discharging overboard. A poorly placed sampling point can also make the meter read low while oil goes overboard. Both points have come up in port State control (PSC) inspections.

Equipment involved

  • Oily water separator (OWS) with a 15 ppm bilge alarm (oil content meter).
  • Overboard discharge line.
  • Sampling line from the overboard line to the ppm unit.
  • 3-way valve. On alarm, it sends the effluent back to the bilge holding tank.

Point 1: a closed or blocked sampling line is not seen as a fault

  • If the sampling line to the ppm unit is closed or blocked, the OWS may keep running.
  • The 3-way valve may not change over to recirculation, so discharge overboard can continue.
  • The ppm unit has no way to detect that no sample is reaching it.
  • I link this to JOWA systems. We have also seen the same behaviour on systems from major Japanese vendors that use the Bilgemon488 15 ppm monitor with no pressure switch in the ppm unit. A pressure switch would detect low sample flow or pressure.
  • My advice: if the sampling pipe has a valve, remove it or seal it in the open position, and write an entry in the Oil Record Book.

Point 2: the sample may not represent the effluent

  • The position of the sampling point on the overboard line matters.
  • Problem cases: the sample is taken from a horizontal pipe section, or far from the separator outlet.
  • In a horizontal pipe, oil and water separate by density, so the sample can be water only.
  • The meter can read low while oil is going overboard.
  • Better: take the sample from a vertical pipe section, close to the separator outlet.

Class and rules

  • Any change to OWS piping needs Class confirmation first. This includes removing the sampling valve or moving the sampling point.
  • Reference documents I keep on this: an ABS regulatory news letter to industry about OWS issues and flow switches; DNV Technical and Regulatory News No. 15/2023; and an AMSA marine notice (2024-03) on testing and inspection of oil filtering equipment, covering how MEPC.107(49) is interpreted for equipment installed after 2005 and what PSC inspectors should check. I have not summarised their content here.

What this note doesn't cover

  • A specific ship, incident or readings, or a maker service letter.
  • Whether fitting a pressure or flow switch to the ppm unit is an approved fix. The ABS document title mentions a flow switch, but I haven't described what it requires.
  • This is general, preventive advice, not the result of one confirmed fault case.