0 rating0 commentsWhen to replace a radar magnetronKnowledgeNavigationI replace X-band and S-band radar magnetrons on condition (magnetron current and performance tests), not on running hours alone, and I always keep a spare on board. The maker's hour interval is a…Anonymous · 4 y