Alfa Laval S956: "Bowl speed low" alarm during separation

PurifierAlfa Laval S956Bowl speed low

Contents
  1. Symptoms
  2. Checked
  3. Diagnosis
  4. Fix
  5. Result
  6. Comments · 0

Symptoms#

  • "Bowl speed low" alarm about twice a day.
  • The alarm came during separation, not during discharge. Often it came about 10 hours into the cycle.
  • Between alarms the separator started, reached speed and worked normally.

Checked#

CheckResult
Belt and friction clutchReplaced — no change
BearingsReplaced recently at major overhaul
SeparatorFully dismantled and cleaned at overhaul
Bowl speed, compared with the other purifierSame on both: 7700–7800 rpm
Speed sensorReplaced — no change
Several discharges in a rowNo problem

Diagnosis#

The cause was the control parameter for the bowl closing water pulses (how often the closing water valve is pulsed during separation). It was set to 5 minutes.

Fix#

Changed the closing water pulse parameter from 5 minutes to 2 minutes.

Result#

The alarm stopped.