Alfa Laval SA805 lube oil separator: bowl opens by itself after about 10 hours
EL-0045 · Solved · rating 0 · works for 0 engineers · occurred 27 Dec 2021
Source: /cases/el-0045
Symptoms#
- The separator ran for about 10 hours, then the bowl opened by itself.
- The closing water went to the drain, and nothing held the bowl closed.
- Alarm: "Low back pressure".
- The other two separators worked normally with the same settings.
Checked#
| Check | Result |
|---|---|
| Overhaul | A previous overhaul used a kit for the 815 model. Overhauled again with the 805 kit — fault came back |
| Seals | All new, original |
| Operating water system and filter | Checked, filter cleaned |
| SV16 make-up interval | Changed from 15 to 10 min, as in the manual — helped for about a month only |
| Motor load | Normal |
| Belt | New |
Giving more closing water (longer fill time) kept the bowl closed. This is not a real fix: it only covers the leak, and the extra water goes into the sludge.
Diagnosis#
The bowl parts that hold the closing water were worn. Even with new seals, they sat loose, so the closing water leaked out. The same parts on another separator sat very tightly.
Fix#
Fitted these bowl parts from another separator.
Result#
- The bowl stays closed. After one day of running there was no problem.
- With the original settings, the closing water now overflows as it should, so the water is held in the bowl.