Log inJoin

Alfa Laval PA605 will not start after emergency stop is released

PurifierAlfa Laval PA605Emergency button press

Contents
  1. Symptoms
  2. Checked
  3. Diagnosis
  4. Fix
  5. Comments · 0

Symptoms#

  • The emergency stop button was pressed.
  • After the button was released, the pump and the separator would not start.
  • The alarm "Emergency button press" stayed on.

Checked#

  • Emergency stop button: released.
  • Button and its contacts tested for continuity: OK, as per the wiring diagram. No stuck contacts.

Diagnosis#

No fault. The manual says that on this system, after the emergency stop button is released, you must wait up to 15 minutes. Only then does the control circuit work again.

Fix#

After releasing the emergency stop, wait up to 15 minutes before you try to start the pump and the separator.

Comments · 0

No comments yet.

Sign in to comment, vote and confirm fixes.Sign in