Symptoms#

  • Unit 1 of the main engine was overhauled. Tests in port were normal.
  • About 10 minutes after leaving port, the unit started knocking and lost compression.
  • After a restart the unit worked again, but after 10 minutes it lost compression again.
  • The hydraulic pipe to the exhaust valve of this unit was 10–15 °C hotter than on the other units.
  • MPC channel 34 was changing between 6 and 14 mA.

Checked#

CheckResult
FIVA valve and fuel pumpFuel goes to the cylinder
Air in the hydraulic systemNone
Cone at the exhaust valve hydraulic pipe connectionIn place
Gap between flange and exhaust valve4 mm, same as before overhaul and as other units
Start orderAir spring air first, then hydraulic oil
Indicator cockOnly light smoke, no compression, no firing

Diagnosis#

A rag had been left inside the exhaust valve hydraulic pipe when the pipe was fitted after the overhaul. Oil could not pass freely to the exhaust valve.

Fix#

  1. Removed the rag from the pipe. It stayed in the pipe and did not go further into the system.
  2. Next step: open and check the filters, the other units and the crankcase, to make sure no pieces of rag are blocking anything else.