OceanGuard BWTS: "EUT Power Abnormal" 10 s after start
EL-0016 · Solved · rating 0 · works for 0 engineers · occurred 10 Oct 2023
Source: /cases/el-0016
Symptoms#
- The BWTS worked normally 3 days before.
- Now, about 10 seconds after start, the alarm "EUT Power Abnormal Alarm" came up and the system stopped.
- The EUT power unit got its supply: LEDs on all modules and its display came on. But EUT voltage and current stayed at 0.
- The local display of the EUT power unit showed "water pressure alarm 1".
- On one start the voltage rose to 9 V and the current to 108 A, then the unit shut down at once.
Checked#
| Check | Result |
|---|---|
| Remote and local control panels switched off and on | No change |
| 440 V and 110 V supply to the system switched off at the MSB, then on | No change |
| EUT power unit temperature (shutdown above 45 °C) | 19 °C — OK |
| Cooling water pressure switch (opened and tested) | Operates |
Diagnosis#
The manual lists two shutdowns for the EUT power unit: temperature above 45 °C and the cooling water pressure switch. Here it was the pressure switch.
- The fresh water tank for EUT cooling was empty, because of a leak on the cooler.
- Even with water, the cooling pump gave only 0.5 kg/cm². The manual says 2–3 kg/cm².
Fix#
- Filled the cooling fresh water tank.
- Adjusted the pressure with the manual valve on the EUT power cooling water outlet to 2.5 kg/cm².
- Started the system.
Result#
The system started and ran normally.
Comments · 0
No comments yet.