Log inJoin

BWTS valve with Siemens SIPART PS2 positioner: alarm A29, valve limit switch

Ballast SystemSiemens SIPART PS2 6DR5020-0NG30-0AB0A29

Contents
  1. Symptoms
  2. Diagnosis
  3. Fix
  4. Comments · 0

Symptoms#

  • The ballast water treatment system gave alarm A29: limit switch fault on a valve.
  • The limit switch is inside the valve positioner, wired to terminals 41–42.
Positioner with the cover off: limit switch module (terminals 41–42 and 51–52) and its setting wheels
Positioner with the cover off: limit switch module (terminals 41–42 and 51–52) and its setting wheels

Diagnosis#

Vibration had loosened a bolt from the board inside the positioner. The bolt fell between one of the setting wheels and the limit switch, so the switch did not work as it should.

Fix#

Removed the loose bolt from the limit switch module.

Comments · 0

No comments yet.