BWTS in muddy ports: filters clog, how to ballast and when to bypass

Ballast System

Contents
  1. Scope
  2. Safety
  3. Tools & parts
  4. Steps
  5. Check after
  6. Comments · 0

Scope#

Ballasting in very muddy water clogs and can damage the BWTS filter; this note covers how I ballast in those ports and when a bypass is allowed. In my experience this happens mostly in Chinese ports. The high sediment load blocks the filter, and the system may then trip or stop working.

It applies to ballast water treatment systems with filters, and to units that use electrolysis. I have no ship type, maker, model, alarm text or readings to give. The only known cause is high sediment load that clogs the filter.

Safety#

  • A bypass is the last resort. It is not a normal way to protect the filter.
  • Do not bypass the BWTS on your own decision. You need approval from the flag state or the RO (class). The port authority may also need to agree.
  • Keep shear force and bending moment inside their limits during ballasting.

Tools & parts#

No tools or spare parts are needed beyond normal ship's equipment. The documents involved are:

  • Ballast Water Record Book
  • Company SMS
  • IMO circular BWM.2/Circ.62

Steps#

Keeping the BWTS running. This has worked on one ship I know of; I have no wider confirmation.

  1. Before the ship arrives in port, clean the filters and the electrolyzers.
  2. Set the flow through the filter to its minimum by hand.
  3. Start ballasting as early as the shear force and bending moment limits allow.
  4. Backflush the filter by hand, so the system does not trip.

If the BWTS still cannot run:

  1. Ask for approval from the flag state or the RO. Ask the port authority if needed.
  2. Only then bypass the system.
  3. Write the bypass in the Ballast Water Record Book.
  4. Tell the flag state and follow the company SMS.
  5. After you leave port, do a ballast water exchange.

Be aware that if the system trips during ballasting, the port can set its own conditions. This can bring delays and extra costs.

Check after#

I have no final outcome, no readings such as filter differential pressure or flow rate, and no parts were replaced.

On the rules side: when I first looked into this, no IMO instrument covered the case. At MEPC 79 (December 2022) the committee could not choose between contingency measures and new operational guidance. It asked for proposals for MEPC 80 (June 2023) and said again that bypass is the last resort. I don't know what MEPC 80 decided. Check the current IMO guidance before you act.