Alfa Laval plate FWG: high brine temperature (60 °C) and low output
EL-0030 · Solved · rating 0 · works for 0 engineers · occurred 14 Jan 2026
Source: /cases/el-0030
Symptoms#
- Low fresh water output and brine temperature up to 60 °C.
- Cleaning the plates did not help. Vacuum and heating water were normal.
Readings, the same before and after cleaning:
| Reading | Value |
|---|---|
| Heating water in / out | 85–88 °C / 70–75 °C |
| Sea water temperature | 25 °C |
| Vacuum | −0.95 to −1.0 kgf/cm² |
| Brine temperature | 60 °C |
| Sea water pressure (own pump) | 3 bar (manual: 2.5–4 bar) |
Checked#
- Plates clean and chemically cleaned, new gaskets.
- Plate pack reassembled correctly and tightened to the calculated dimension.
- Pressure test: no leaks, no pressure drop.
- All valves in order.
- Feed water valve fully open. Closing it by about 30% changed little.
- Vacuum good.
Diagnosis#
The symptoms pointed to poor sea water flow through the unit. The ejector pump was not giving enough flow, even though the vacuum was still good. Brine was not removed well, so the feed water flow stayed low.
Fix#
Replaced the ejector pump (done in port).
Result#
- Brine temperature and output back to normal.
- Vacuum did not change (about −1 kgf/cm²).
- Brine outflow improved and feed water flow increased.