Alfa Laval plate FWG: vacuum lost and will not come back past 60 %
EL-0050 · Solved · rating 0 · works for 0 engineers · occurred 08 Feb 2022
Source: /cases/el-0050
Symptoms#
- First the salinity started to jump.
- One hour later the water level went out of the sight glass and the vacuum fell to 30 %.
- It all happened within a few hours. Before that, the vacuum built up in 30 seconds.
Checked#
| Check | Result |
|---|---|
| Evaporator | Cleaned |
| Air leak | Found one and repaired it |
| Vacuum after the repair | Stuck at 60 %, would not go further |
| Vacuum with the ejector pump stopped | Held at 60 % for 30 minutes — no more leaks |
| Ejector pump discharge pressure | 3.8 bar (manual: up to 3 bar) |
| Back pressure after the ejector | None |
| Level in the sight glass | As per manual |
Diagnosis#
The condenser was blocked on the sea water side. It had been cleaned two months before, but it picked up weed in port. The pressures all looked normal, so this was not seen at first.
Fix#
Opened and cleaned the condenser.
A faster way to find this next time: check the pressure drop across the condenser on the sea water side, or the feed water pressure at the evaporator inlet.