Alfa Laval plate FWG: vacuum lost and will not come back past 60 %

Fresh Water GeneratorAlfa Laval

Contents
  1. Symptoms
  2. Checked
  3. Diagnosis
  4. Fix
  5. Comments · 0

Symptoms#

  • First the salinity started to jump.
  • One hour later the water level went out of the sight glass and the vacuum fell to 30 %.
  • It all happened within a few hours. Before that, the vacuum built up in 30 seconds.

Checked#

CheckResult
EvaporatorCleaned
Air leakFound one and repaired it
Vacuum after the repairStuck at 60 %, would not go further
Vacuum with the ejector pump stoppedHeld at 60 % for 30 minutes — no more leaks
Ejector pump discharge pressure3.8 bar (manual: up to 3 bar)
Back pressure after the ejectorNone
Level in the sight glassAs per manual

Diagnosis#

The condenser was blocked on the sea water side. It had been cleaned two months before, but it picked up weed in port. The pressures all looked normal, so this was not seen at first.

Condenser plate pack opened: the sea water port is blocked with weed
Condenser plate pack opened: the sea water port is blocked with weed

Fix#

Opened and cleaned the condenser.

A faster way to find this next time: check the pressure drop across the condenser on the sea water side, or the feed water pressure at the evaporator inlet.