Fresh water generator: checklist for low output or high salinity
EL-0158 · Procedure · rating 0 · occurred 04 Sept 2022
Source: /cases/el-0158
Scope#
This is my checklist for a fresh water generator (FWG) that makes too little water or gives high salinity in the distillate. It applies to a vacuum evaporator heated by engine jacket water, where an ejector pump drives the vacuum ejector and also sends sea water through the condenser.
It is general, not from a real fault case, and not tied to a maker, model or vessel. It has no normal values or limits for pressure, temperature, vacuum or salinity; take these from the maker manual.
I put the checks in three groups:
- A. Low output, vacuum normal
- B. Low output, vacuum poor
- C. High salinity in the distillate
Safety#
I have no special safety notes here. Follow the maker manual and the ship's safety procedures before you open, clean or work on any part of the plant. Do not bypass the salinometer or the dump valve to keep the plant running.
Tools & parts#
- Thermometers on the FWG: jacket-water inlet and outlet, shell, sea-water inlet and outlet of the condenser
- Vacuum gauge and ejector pressure gauges (the checks need them)
- Sounding tape or tank gauges for the fresh water tanks
- Chemicals for evaporator cleaning, or a drill for blocked tubes (I give no product or method)
- Wear (mouth) rings for the distillate pump, if worn
- An FWG operation data sheet to log readings (see Check after)
Steps#
A. Low output, vacuum normal
- Check heat transfer in the evaporator. Read the jacket-water inlet and outlet thermometers and compare them.
- Large temperature drop: make sure the jacket-water inlet and outlet valves are fully open. Make sure the bypass valve is fully closed.
- Small temperature drop: the evaporator is fouled. Clean it with chemicals, or drill out blocked tubes.
- Normal drop, but both temperatures low: the heat supply is the problem. The main engine load is low, or the jacket-water cooler keeps the temperature too low.
- Check heat transfer in the condenser. Read the shell and sea-water thermometers.
- Shell temperature high and a large sea-water inlet/outlet difference: sea-water flow from the ejector pump is too low. The pump may be worn.
- Small sea-water inlet/outlet difference: the condenser is fouled or blocked.
- Check the distillate (fresh water) pump. A worn pump loses suction. Renew the wear (mouth) rings.
- Check the flowmeter. It may read wrong. Find the real output by sounding or measuring the fresh water tanks.
- Check the piping and fittings after the distillate pump for leaks or blockages.
B. Low output, vacuum poor
- Look for air leaks:
- the air valve on the FWG body;
- the sight-glass joints;
- the shell;
- the seal of the distillate pump;
- the non-return valve after the distillate pump.
- Check for low pressure at the ejector inlet:
- the ejector pump suction, discharge and overboard valves must be fully open;
- clean the suction strainer of the ejector pump if dirty;
- check the ejector pump for wear.
- If the pressure on the outlet side of the ejector is low, check the ejector nozzle (orifice). It may be worn or blocked.
C. High salinity in the distillate
- Check the salinometer. It may be faulty.
- Check the solenoid (dump) valve that the salinometer controller operates. It may be faulty or leaking.
- Check the demister. It may be fouled.
Check after#
- Confirm the real output by sounding the fresh water tanks, not only by the flowmeter.
- Check that vacuum and salinity are back within the maker limits.
- Keep an FWG operation data sheet, a regular log of readings. It helps to trace faults.
- This checklist is not from a real repair, so there is no outcome to report.