Log inJoin

Kongsberg DGU 8800e governor switches off a few minutes after start

Main EngineAutomation / PLCKongsberg DGU 8800e

Contents
  1. Symptoms
  2. Checked
  3. Diagnosis
  4. Fix
  5. Result
  6. Comments · 0

Symptoms#

  • The main engine governor unit would not stay on.
  • After the power button inside the unit, two green LEDs lit. The unit tried to boot, then switched off.
  • When cold (after being off for a while), it started. After a few minutes it began to blink and went off.
DGU 8800e governor panel in the engine control console (circled)
DGU 8800e governor panel in the engine control console (circled)

Checked#

  • 26 V supply to the unit: present.

Diagnosis#

The internal power supply lost its 5 V output when it got hot. One of the two large capacitors on the power supply board overheated, and then the 5 V dropped. At the same moment a red LED marked "5V" on another board lit up.

Fix#

  1. Temporary: fitted a small cooling fan inside the unit to cool the power supply.
  2. Ordered a new power supply.
  3. When fitting the new power supply, set its output under load to not less than 5 V. Check the other output voltages too: if they drop even a little, the unit again starts and goes off.
DGU 8800e opened, with a temporary cooling fan fitted on the right
DGU 8800e opened, with a temporary cooling fan fitted on the right

Result#

With the extra fan, the governor works normally until the new power supply arrives.

Comments · 0

No comments yet.

Sign in to comment, vote and confirm fixes.Sign in