Kongsberg DGU 8800e governor switches off a few minutes after start
EL-0054 · Solved · rating 0 · works for 0 engineers · occurred 08 Oct 2022
Source: /cases/el-0054
Symptoms#
- The main engine governor unit would not stay on.
- After the power button inside the unit, two green LEDs lit. The unit tried to boot, then switched off.
- When cold (after being off for a while), it started. After a few minutes it began to blink and went off.
Checked#
- 26 V supply to the unit: present.
Diagnosis#
The internal power supply lost its 5 V output when it got hot. One of the two large capacitors on the power supply board overheated, and then the 5 V dropped. At the same moment a red LED marked "5V" on another board lit up.
Fix#
- Temporary: fitted a small cooling fan inside the unit to cool the power supply.
- Ordered a new power supply.
- When fitting the new power supply, set its output under load to not less than 5 V. Check the other output voltages too: if they drop even a little, the unit again starts and goes off.
Result#
With the extra fan, the governor works normally until the new power supply arrives.