Log inJoin

Nabtesco governor: main engine will not go above 66 rpm, SCAVEN. LIMIT lamp on

Main EngineAutomation / PLCNabtesco governor control unitM/E GOVERNOR SYSTEM ABNR

Contents
  1. Symptoms
  2. Checked
  3. Diagnosis
  4. Fix
  5. Comments · 0

Symptoms#

  • The main engine would not run faster than 66 rpm (Half Ahead).
  • Scavenge air pressure was 0.2 bar. The auxiliary blowers were still running.
  • On the governor control unit the SCAVEN. LIMIT lamp was on.
Governor control unit: SCAVEN. LIMIT lamp on
Governor control unit: SCAVEN. LIMIT lamp on
  • With LIMIT CANCEL active, the engine started to speed up, but came back to 66 rpm.
  • Then the ACTUATOR and VIT CONTROL lamps came on. The alarm system showed "M/E GOVERNOR SYSTEM ABNR" and "M/E VIT CONT ABNR".
After LIMIT CANCEL: ACTUATOR and VIT CONTROL lamps on
After LIMIT CANCEL: ACTUATOR and VIT CONTROL lamps on

Checked#

  • Scavenge air pressure sensor: replaced, no change.

Diagnosis#

The wing knob of the governor manual control was not in its limit switch position. It had been knocked during cleaning.

Fix#

Put the knob back to its limit switch position.

Comments · 0

No comments yet.

Sign in to comment, vote and confirm fixes.Sign in