Nabtesco governor: main engine will not go above 66 rpm, SCAVEN. LIMIT lamp on
EL-0057 · Solved · rating 0 · works for 0 engineers · occurred 23 Mar 2023
Source: /cases/el-0057
Symptoms#
- The main engine would not run faster than 66 rpm (Half Ahead).
- Scavenge air pressure was 0.2 bar. The auxiliary blowers were still running.
- On the governor control unit the SCAVEN. LIMIT lamp was on.
- With LIMIT CANCEL active, the engine started to speed up, but came back to 66 rpm.
- Then the ACTUATOR and VIT CONTROL lamps came on. The alarm system showed "M/E GOVERNOR SYSTEM ABNR" and "M/E VIT CONT ABNR".
Checked#
- Scavenge air pressure sensor: replaced, no change.
Diagnosis#
The wing knob of the governor manual control was not in its limit switch position. It had been knocked during cleaning.
Fix#
Put the knob back to its limit switch position.