Yanmar generator: HT cooling water outlet 6 °C hotter than on the other engine

Auxiliary EngineYanmar (450 kW)

Contents
  1. Symptoms
  2. Checked
  3. Diagnosis
  4. Fix
  5. Comments · 0

Symptoms#

  • Two Yanmar 450 kW generators in parallel, about 300 kW each.
EngineHT inletHT outlet
Engine 176 °C80 °C
Engine 276 °C86 °C

Checked#

  • Replaced the thermostats: no change.

Diagnosis#

A piece of insulation had come off the exhaust manifold, right next to the HT outlet thermometer. Heat from the bare manifold made the thermometer read high. The cooling system itself was not the problem.

Fix#

Put the insulation back on the exhaust manifold next to the thermometer.