▲0 rating0 comments220 V insulation alarm every morning, gone before you reach the switchboardTroubleshootingElectrical · Low insulation 220 VLow insulation alarm on the 220 V system early every morning, at breakfast time. By the time the engineer reached the switchboard, the reading was normal again. It started when a new cook joined the…Anonymous · 2 y▲0 rating0 commentsSodium lamp fittings: insulation slowly drops to zero after warm-upTroubleshootingElectricalAfter the high-pressure sodium lamps warmed up, the insulation reading slowly fell and went to zero.Anonymous · 4 y▲0 rating0 commentsEmergency generator: insulation drops to 0.1 MΩ at every startTroubleshootingElectrical · Low insulation 440 VEvery time the emergency generator started, the 440 V insulation monitor fell to 0.1–0.2 MΩ. After 2–3 hours of running, the reading slowly came back to normal (5 MΩ and higher). The ship had been…Anonymous · 7 y▲0 rating0 commentsMain switchboard low insulation: find the fault by isolating loadsProcedureElectrical · Low insulationThis is how I find the cause of a low insulation alarm or low reading on the main switchboard (MSB): isolate all loads, then reconnect them one at a time while watching the insulation monitor. It…Anonymous · 4 y▲0 rating0 commentsHyundai generator: no voltage at start after a 440 V insulation alarmTroubleshootingElectrical · Hyundai HFC7The 440 V insulation reading started to jump between 0 and infinity. Three generators were on the bus. Two were taken off, only No. 3 was left. Next day generator No. 1 was started, but it did not…Anonymous · 4 y▲0 rating0 commentsYanmar generator: HT cooling water outlet 6 °C hotter than on the other engineTroubleshootingAuxiliary Engine · Yanmar (450 kW)Two Yanmar 450 kW generators in parallel, about 300 kW each. Engine HT inlet HT outlet Engine 1 76 °C 80 °C Engine 2 76 °C 86 °CAnonymous · 2 y▲0 rating0 commentsSwitchboard earth lamps do not light, only one of three on lamp testTroubleshootingElectricalThe insulation resistance monitor (IRM) worked normally. The earth lamps did not light. With the test button pressed, only one of the three lamps lit.Anonymous · 3 mo▲0 rating0 commentsShipboard electric motors: routine maintenance checks and testsKnowledgeElectricalPreventive maintenance of shipboard electric motors comes down to daily attention plus a few periodic checks and tests. The best thing I know is an electro-technical officer (ETO) on board who…Anonymous · 4 y▲0 rating0 commentsAlpha Lubricator: "Feedback failure" slowdown comes and goesTroubleshootingMain Engine · MAN B&W Alpha Lubricator · Feedback failureMain engine slowdown from the Alpha Lubricator system, alarm "Feedback failure". The alarm came for 5 to 60 seconds and then cleared by itself. In the menu it showed as Alarm 3. By the manual, Alarm…Anonymous · 4 y▲0 rating0 commentsFire pump 115 kW: main breaker trips at star-delta changeoverTroubleshootingPumpsTwo fire pumps, 115 kW each. One starts normally. The other runs up on star without problems. At the changeover to delta, the main breaker trips. At the changeover, the current goes off the scale of…Anonymous · 6 y▲0 rating0 commentsMain engine fire from a loose two-screw fuel flange (Stena Europe)IncidentMain Engine · Wärtsilä Vasa 32 · Low fuel oil pressure, then ER fire alarmRo-ro ferry, four Wärtsilä Vasa 32 main engines. ME3 was started for arrival in port. Thirteen minutes later the ECR got a low fuel pressure alarm on the port fuel system, the standby fuel pump cut…Anonymous · 1 y▲0 rating0 commentsFatal engine room fire after opening a pressurised fuel filter (Moritz Schulte)IncidentAuxiliary Engine · MAN B&W L23/30H · ER fire alarmLPG carrier discharging alongside in Antwerp. AE2 and AE3 were running and AE1 was on standby. After the morning toolbox talk the newly promoted 3/E asked the 2/E if he could clean the AE1 fuel…Anonymous · 3 y▲0 rating0 commentsMain engine fuel filters burst with both return valves shut (Sandy Ground)IncidentMain Engine · EMD 12V-710 (710GC/L12ME23B) · High fuel filter dP, then low fuel pressure on all four MEsStaten Island ferry, four EMD MEs at 92 % load, 884 people on board. The oilers spent over 40 minutes turning valves to balance the two FO day tanks. In the end, the NTSB concluded, both FO return…Anonymous · 2 y