Search

Cases

0 rating0 commentsYanmar generator: HT cooling water outlet 6 °C hotter than on the other engineTroubleshootingAuxiliary Engine · Yanmar (450 kW)Two Yanmar 450 kW generators in parallel, about 300 kW each. Engine HT inlet HT outlet Engine 1 76 °C 80 °C Engine 2 76 °C 86 °CAnonymous · 2 y0 rating0 commentsFresh water generator: checklist for low output or high salinityProcedureFresh Water GeneratorThis is my checklist for a fresh water generator (FWG) that makes too little water or gives high salinity in the distillate. It applies to a vacuum evaporator heated by engine jacket water, where an…Anonymous · 4 y0 rating0 commentsSauer air compressor keeps tripping, nothing found by handTroubleshootingCompressed Air · SauerThe air compressor tripped again and again for about 1.5 years.Anonymous · 2 y0 rating0 commentsMain engine fire from a loose two-screw fuel flange (Stena Europe)IncidentMain Engine · Wärtsilä Vasa 32 · Low fuel oil pressure, then ER fire alarmRo-ro ferry, four Wärtsilä Vasa 32 main engines. ME3 was started for arrival in port. Thirteen minutes later the ECR got a low fuel pressure alarm on the port fuel system, the standby fuel pump cut…Anonymous · 1 y0 rating0 commentsStandard bearing shell on an undersize journal: con-rods break out (Ocean Guardian)IncidentAuxiliary Engine · Caterpillar 3516B · No alarm; loud bang, then smoke and fire in ERDiesel-electric offshore supply vessel, four Caterpillar 3516B main DGs (1,990 kW each). All four were overhauled by shore technicians in early 2022. On sea trials, DG3 had run about 4 h since…Anonymous · 3 y0 rating0 commentsHFO to MGO changeover: cool slowly and watch viscosityProcedureMain EngineChanging the main engine and diesel generators from HFO to MGO is safe if fuel temperature falls slowly and viscosity stays between 2 cSt and 20 cSt. This is the general procedure I use; it follows…Anonymous · 3 y