Log inJoin

Running the exhaust gas economizer dry: soot fire risk and precautions

BoilerMain Engine

Contents
  1. Scope
  2. Safety
  3. Tools & parts
  4. Steps
  5. Check after
  6. Comments · 0

Scope#

An exhaust gas economizer (exhaust gas boiler) can be run dry in an emergency, but the main risk is a soot fire: with no water inside, the tubes run hotter. This procedure lists the precautions I take. It is general practice, not tied to a maker or model, and not from a real case.

It does not cover:

  • how to isolate the economizer from the steam and water system;
  • how long the economizer can safely run dry;
  • any maker service letter or class notice.

Safety#

  • Soot fire is the main hazard. Without water, the tubes get hotter, and soot deposits can catch fire more easily.
  • The real temperature limits and steps for dry running come from the maker. Read the dry running section of the maker's manual before you start, and follow it.
  • Do not rely on gauges you have not checked. The gas temperature gauges and the U-tube manometer must work correctly before and during dry running.

Tools & parts#

  • Water washing equipment for the gas side (if washing is possible)
  • Soot blowers
  • Gas inlet and outlet temperature gauges
  • U-tube manometer for the gas-side pressure drop
  • Maker's manual (dry running section)

Steps#

  1. If you can, water wash the gas side before you start dry running.
  2. Check that the gas inlet and outlet temperature gauges work correctly.
  3. Check that the U-tube manometer (gas-side pressure drop) works correctly.
  4. Open the economizer vent valves and drain valves. Keep them open while the economizer runs dry.
  5. Soot blow more often than normal: 3 to 4 times a day.
  6. Watch the gas inlet and outlet temperatures closely.
  7. Do not let the temperature inside the economizer go above 400 °C. This limit can differ by maker, so use the maker's figure.
  8. Do not run the main engine at low load for long periods.
  9. Watch the draught loss (back pressure) across the economizer. If it goes up, soot blow more.
  10. At the first chance, open the economizer and inspect it inside. Make a permanent repair.

Check after#

  • The temperature inside the economizer stays below the maker's dry running limit (400 °C as above, but it can change by maker).
  • Draught loss across the economizer does not keep rising after soot blowing.
  • The internal inspection and permanent repair are done at the first chance.
  • I have no result from a real dry running case.

Comments · 0

No comments yet.

Sign in to comment, vote and confirm fixes.Sign in