An exhaust gas economizer (exhaust gas boiler) can be run dry in an emergency, but the main risk is a soot fire: with no water inside, the tubes run hotter. This procedure lists the precautions I take. It is general practice, not tied to a maker or model, and not from a real case.
It does not cover:
- how to isolate the economizer from the steam and water system;
- how long the economizer can safely run dry;
- any maker service letter or class notice.
Safety#
- Soot fire is the main hazard. Without water, the tubes get hotter, and soot deposits can catch fire more easily.
- The real temperature limits and steps for dry running come from the maker. Read the dry running section of the maker's manual before you start, and follow it.
- Do not rely on gauges you have not checked. The gas temperature gauges and the U-tube manometer must work correctly before and during dry running.
Tools & parts#
- Water washing equipment for the gas side (if washing is possible)
- Soot blowers
- Gas inlet and outlet temperature gauges
- U-tube manometer for the gas-side pressure drop
- Maker's manual (dry running section)
Steps#
- If you can, water wash the gas side before you start dry running.
- Check that the gas inlet and outlet temperature gauges work correctly.
- Check that the U-tube manometer (gas-side pressure drop) works correctly.
- Open the economizer vent valves and drain valves. Keep them open while the economizer runs dry.
- Soot blow more often than normal:
3 to 4times a day. - Watch the gas inlet and outlet temperatures closely.
- Do not let the temperature inside the economizer go above
400 °C. This limit can differ by maker, so use the maker's figure. - Do not run the main engine at low load for long periods.
- Watch the draught loss (back pressure) across the economizer. If it goes up, soot blow more.
- At the first chance, open the economizer and inspect it inside. Make a permanent repair.
Check after#
- The temperature inside the economizer stays below the maker's dry running limit (
400 °Cas above, but it can change by maker). - Draught loss across the economizer does not keep rising after soot blowing.
- The internal inspection and permanent repair are done at the first chance.
- I have no result from a real dry running case.