▲0 rating0 commentsPods stuck at 90° after overspeed trip and a latched water-leak stop (Spirit of Discovery)IncidentPropulsion & Thrusters · Siemens SISHIp eSiPOD (SiPOD-M10) · Pod water leakage stop (WLS) sequence alarm, then propeller overspeedCruise ship with two Siemens eSiPOD pods (6,500 kW each, no rudder), crossing the Bay of Biscay in force 8–9 wind and 8–9 m waves. At 12:30 the port pod gave a WLS sequence alarm. Very soon after, it…Anonymous · 8 mo▲0 rating0 commentsEngine room flooding from a corroded sea water pipe at the strainer (Oliver Hazard Perry)IncidentAuxiliary Engine · John Deere diesel generator · AC power fault alarm on fire alarm panel, blackoutSail training tall ship (128 ft), two Caterpillar C12 propulsion engines, two John Deere DGs (99 kW). Moored, one crewmember on board. Shore power breakers kept tripping, so the port DG ran…Anonymous · 7 mo▲0 rating0 commentsMain engine fuel filters burst with both return valves shut (Sandy Ground)IncidentMain Engine · EMD 12V-710 (710GC/L12ME23B) · High fuel filter dP, then low fuel pressure on all four MEsStaten Island ferry, four EMD MEs at 92 % load, 884 people on board. The oilers spent over 40 minutes turning valves to balance the two FO day tanks. In the end, the NTSB concluded, both FO return…Anonymous · 2 y