Pods stuck at 90° after overspeed trip and a latched water-leak stop (Spirit of Discovery)
Incident
Propulsion & Thrusters
·
Siemens SISHIp eSiPOD (SiPOD-M10)
·
Pod water leakage stop (WLS) sequence alarm, then propeller overspeed
Cruise ship with two Siemens eSiPOD pods (6,500 kW each, no rudder), crossing the Bay of Biscay in force 8–9 wind and 8–9 m waves. At 12:30 the port pod gave a WLS sequence alarm. Very soon after, it…
Anonymous · 8 mo
▲
0
rating
0
comments
Doosan emergency generator: testing overspeed without a test button
Knowledge
Auxiliary Engine
·
Doosan AD136TS, KMC ECMS-850EH
·
Overspeed
The set: Doosan AD136TS engine (1800 rpm, 125 kW) with a KMC ECMS-850EH engine control and monitoring system. The wiring diagram in the manual shows a GAC ESD5550 speed control unit with "TEST…
Anonymous · 3 y