MacGregor crane: alarm 93 "Encoder wrong position", crane stops

Deck MachineryMacGregor93 Encoder wrong position

Contents
  1. Symptoms
  2. Checked
  3. Fix
  4. Result
  5. Comments · 0

Symptoms#

  • Alarm 93 "Encoder wrong position" on the hoisting and luffing MPC.
  • After one MPC was replaced, the alarm still came, but the crane could be operated.
  • An hour later the alarm came again and the crane could not be operated.
  • Pressing the button on the MPC cleared the alarm, but it came back after 5–6 seconds and the crane stopped again.

Checked#

CheckResult
Cables, supply voltageVoltage present
MPC replacedAlarm stayed
Encoder and its connectionsOK — no change
Encoder calibrationNo change
Limit switch adjustmentNo change

Fix#

Replaced the luffing winch angle encoder.

Result#

The crane worked at once, even without calibrating the new encoder.

Comments · 0

No comments yet.