MacGregor crane: alarm 93 "Encoder wrong position", crane stops
EL-0044 · Solved · rating 0 · works for 0 engineers · occurred 11 Dec 2021
Source: /cases/el-0044
Symptoms#
- Alarm 93 "Encoder wrong position" on the hoisting and luffing MPC.
- After one MPC was replaced, the alarm still came, but the crane could be operated.
- An hour later the alarm came again and the crane could not be operated.
- Pressing the button on the MPC cleared the alarm, but it came back after 5–6 seconds and the crane stopped again.
Checked#
| Check | Result |
|---|---|
| Cables, supply voltage | Voltage present |
| MPC replaced | Alarm stayed |
| Encoder and its connections | OK — no change |
| Encoder calibration | No change |
| Limit switch adjustment | No change |
Fix#
Replaced the luffing winch angle encoder.
Result#
The crane worked at once, even without calibrating the new encoder.
Comments · 0
No comments yet.