Mitsubishi deck crane will not start after a limit switch stop
EL-0113 · Solved · rating 0 · works for 0 engineers · occurred 15 Jul 2025
Source: /cases/el-0113
Symptoms#
- The crane limit switches were being tested during a class survey.
- A limit switch tripped and the crane stopped.
- After that the crane would not start at all. There were no alarms.
Checked#
- The limit switch was moved off to let the crane start. The crane still did not start.
Diagnosis#
The joystick (control lever) was not in the neutral position. After the stop on the limit switch, the crane stayed in its protection mode and would not start while the lever was out of neutral.
Fix#
Put the joystick back to neutral, then started the crane.
Result#
The crane started and worked normally.