Incinerator will not light: thick white smoke, flame sensor drops out

Incinerator & Sewage

Contents
  1. Symptoms
  2. Checked
  3. Diagnosis
  4. Fix
  5. Result
  6. Comments · 0

Symptoms#

  • The incinerator would not light. The flame sensor lost the flame.
  • Before, it had worked every day.
  • The furnace had not been cleaned for a long time. Both chambers were full of ash, and all the air holes at the bottom were blocked. The furnace was cleaned out.
Ash in the furnace before cleaning; the air holes at the bottom were blocked
Ash in the furnace before cleaning; the air holes at the bottom were blocked

Checked#

  • Flame sensor: it does see the flame when one burner nozzle fires, so it was not changed.

Diagnosis#

There are air pipes at the bottom of the furnace. They were open too wide. After the cleaning, too much air went in. This gave thick white smoke, and the smoke made the flame sensor lose the flame.

Before, the incinerator worked only because ash had blocked these air holes.

Fix#

Closed the air pipes at the bottom of the furnace a little.

Result#

The incinerator lit at once.