Shipboard incinerator: how to keep it in good condition
EL-0161 · Knowledge · rating 0 · occurred 16 Jul 2022
Source: /cases/el-0161
Notes#
Keeping a shipboard incinerator in good condition mostly means clean air inlets and burner parts, a slow shutdown, careful sludge handling and sensible loading. These are the practices I follow, based on what incinerator makers usually recommend. They are general, not tied to a maker, model, fault or alarm.
Daily checks
- Every day, before start-up, look at the chamber air inlets, the outlet and the burner parts. Keep them clean.
Shutdown
- Do not switch off main power until the combustion chamber temperature is below
170 °C. I don't have the reason for this limit.
Sludge handling
- Change the sludge dosing pump stator when there are problems with high chamber temperature, flue gas or sludge dosing control.
- On a plant with only one sludge tank, do not move sludge into the service tank during burning. This can harm the refractory.
- Heat the sludge during the night with the circulation pump off. The next morning, drain off the free water. Only then start the sludge program.
Waste loading
- Glass, lithium batteries and spray cans must not go into the incinerator.
- Too many oily rags or filter cartridges in one load can harm the flue gas fan.
Cooling jacket
- Every
6 months, open the eight cover plates and inspect the cooling jacket. Clean it with steam or hot water if it is dirty.
General
- Work to the instruction manual. Keep the settings as they are unless the maker says to change them.
I have no maker service letters, class rules or other settings to add. The only values here are the 170 °C limit and the 6-month jacket inspection.
Comments · 0
No comments yet.