Teamtec OG400 incinerator: "Communication failure PLC - display" after battery change

Incinerator & SewageAutomation / PLCTeamtec OG400Communication failure PLC - display

Contents
  1. Symptoms
  2. Diagnosis
  3. Fix
  4. Result
  5. Comments · 0

Symptoms#

  • The PLC battery was replaced with the incinerator switched off from the mains.
  • After switching on: "Communication failure PLC - display".
  • All PLC data and settings were lost.

Diagnosis#

The PLC battery must be changed with the incinerator power ON. With the power off and the battery out, the PLC lost its settings.

Fix#

  1. Found the memory module with the incinerator settings. It had been supplied by the maker when the same problem happened before.
  2. Inserted the module into the PLC. The PLC loaded the settings automatically.
  3. Started the incinerator.

Result#

The incinerator works normally.