CPP hub oil loss from a cracked blade foot, not a blade seal (Maunalei)
EL-0124 · Solved · rating 0 · occurred 11 Aug 2022
Source: /cases/el-0124
What happened#
Containership, MAN B&W 7L70MC-C two-stroke ME directly coupled to a 5-blade MAN Mark 5 CPP. On passage to Anchorage an alarm came up: CPP hub head tank empty. The crew reduced pitch and refilled the tank. Everyone suspected a failed blade seal.
On the way to drydock the leak got worse and the oil on board ran out. On the CPP maker's advice, the crew topped up with fresh water to keep pressure on the shared lip seal. Water got into the stern tube oil, its temperature rose, and the ME was stopped. The ship was towed in. No injuries.
Diagnosis#
- Loss rose with load:
1 L/hat full ahead,0.45 L/hat three-quarters ahead. - Hub and stern tube LO have separate head tanks but share the forward lip seal, which works because the hub side is at slightly higher pressure. If hub head is lost, stern tube oil can flow past the seal into the hub.
- Diver survey: fractures at the base of blades no. 2 and no. 4.
- In drydock, oily water seeped from the no. 4 blade foot near bolt holes 4.6 and 4.7: a through-thickness crack. The no. 2 cracks were surface only.
Root cause#
High-cycle fatigue. Ratchet marks showed the cracks started at the edges of the bolt hole counterbores. A cross-section of one counterbore measured a radius of about 0.62 mm; the design radius was 0.8 mm.
The material was also out of spec: Charpy 9.5 J against 21 J at 10 °C, low tensile, yield and elongation, silicon 0.17 % against 0.10 % max. So the no. 4 blade was more prone to fatigue. MAN's FEA showed high stress at the blade foot under the large load changes of normal service. No cracks were found on similar propellers, so NTSB calls this likely an isolated case. MAN later raised the counterbore radius to 4.0 mm, which gave about 40 % more safety factor.
Timeline / response#
| Time | Event |
|---|---|
| 4 Aug, 1723 | Alarm; hub head tank empty. Pitch reduced, tank refilled. |
| 7–8 Aug | Anchorage: can't be fixed alongside. Leaves for drydock in Portland. |
| 11 Aug, 0856 | Leak worse; rpm and pitch reduced. |
| 11 Aug, 1834 | Water in stern tube oil, high temp. ME stopped. |
| 15 Aug, 0437 | Arrived shipyard under tow. Diver finds blade cracks. |
| 17–29 Aug | Drydock: DP test, no. 4 replaced with the spare, no. 2 weld-repaired. |
| 29 Aug–19 Sep | In service limited to 43 % MCR, 90 rpm (normal 108). Then laid up. |
Lessons#
- Don't assume a blade seal. Here the hub oil loss was a through crack in the blade foot. Log the loss rate at each load and get a diver survey or drydock early.
- Watch the hub and stern tube head tanks together. Trend stern tube oil temperature too. If hub head drops, oil and water can cross the shared lip seal.
- Keep enough hub and stern tube oil on board for a long leak. Fresh water kept seal pressure but got into the stern tube oil.
- Reduce rpm and pitch. Less load means less leak and less cyclic stress on the blade foot.
- When blades are off, DP-test the blade foot around every bolt hole and check the counterbore radius against the drawing. For new blades, ask for material test results (Charpy, tensile, chemistry) against spec.
- Know what spare blades you have before drydock. There was only one; no. 2 was weld-repaired, which class rules don't normally allow.
Source: NTSB report MIR-24-11 — Loss of Propulsion aboard Containership Maunalei.
Comments · 0
No comments yet.