Log inJoin

Stern tube oil: high copper, cooler or pump wear suspected

Propulsion & ThrustersPumps

Contents
  1. Symptoms
  2. Checked
  3. Diagnosis
  4. Fix
  5. Result
  6. Answers · 0

Symptoms#

Our stern tube lube oil showed high copper (60-80 ppm); the cause is not confirmed, and I suspect wear in the oil cooler or circulating pumps rather than the bearing.

  • Lab analysis of the stern tube lube oil: copper at 60-80 ppm.

Checked#

CheckResult
Stern tube oil analysis, copper60-80 ppm (high)
Earlier copper trendNot known
Other wear metalsNot known
Water in oilNot known
Bearing materialNot known
Oil type and running hours of the oilNot known

Diagnosis#

The cause is not confirmed.

The answer depends on the bearing type. If the bearing is tin-based, this copper level is not a normal sign of bearing damage. That is an assumption, because I don't know the bearing material here.

Two other possible copper sources, both through wear:

  • the stern tube oil cooler
  • the stern tube circulating pumps

Neither has been checked yet.

Fix#

No fix is done yet. With no drydock planned in the near future, this is what I plan to do:

  1. Drain some of the stern tube oil and top up with new oil.
  2. Give the system enough running time to flush well.
  3. Take fresh oil samples and send them to the lab.
  4. Open and check the filters of the stern tube circulating pumps.
  5. Follow the copper value in the next results to see the trend.

Result#

I don't have the final result yet.

Answers · 0

No answers yet. Seen this before? Your reading could close it.

Seen this fault? Sign in to answer.Sign in