ISO 4406 vs ISO 4407: oil cleanliness code vs particle counting
EL-0173 · Knowledge · rating 0 · occurred 22 Mar 2024
Source: /cases/el-0173
Notes#
ISO 4406 is the cleanliness code MAN refers to for main engine system oil on its electronically controlled 2-stroke engines (ME type); ISO 4407 and ISO 11500 are particle counting methods. This note explains the difference and how I check oil cleanliness on ME-B and ME-C engines.
ISO 4406 vs ISO 4407 / ISO 11500
| Standard | What it is | Used by MAN? |
|---|---|---|
| ISO 4406 | A code that shows how clean the oil is, based on how many particles there are in each size group | Yes, this is the one MAN refers to |
| ISO 4407, ISO 11500 | Methods for counting the particles | Counting methods, not the cleanliness code |
In short: ISO 4406 = the cleanliness code. ISO 4407 / ISO 11500 = particle counting methods.
MAN guidance and practice
- The MAN ES filtration handbook is the general rule for oil cleanliness on ME-B and ME-C engines. I don't have its document number.
- MAN accepts checking oil samples under a microscope.
- When the sample is very dark (dark brown or black), you cannot see the particles well, so the oil needs filtering before the check.
- But that filter holds back part of the particles, so the count you get is changed by this step.
What this note doesn't cover
- Target cleanliness codes, particle size groups and filter fineness in microns.
- Hydraulic oil requirements, sampling points and sampling intervals.
- MAN service letter numbers, or any real fault case.
For these values, check the MAN ES filtration handbook and the engine documentation.
Comments · 0
No comments yet.