ISO 4406 vs ISO 4407: oil cleanliness code vs particle counting

Main EngineMAN Energy Solutions ME / ME-B / ME-C

Notes#

ISO 4406 is the cleanliness code MAN refers to for main engine system oil on its electronically controlled 2-stroke engines (ME type); ISO 4407 and ISO 11500 are particle counting methods. This note explains the difference and how I check oil cleanliness on ME-B and ME-C engines.

ISO 4406 vs ISO 4407 / ISO 11500

StandardWhat it isUsed by MAN?
ISO 4406A code that shows how clean the oil is, based on how many particles there are in each size groupYes, this is the one MAN refers to
ISO 4407, ISO 11500Methods for counting the particlesCounting methods, not the cleanliness code

In short: ISO 4406 = the cleanliness code. ISO 4407 / ISO 11500 = particle counting methods.

MAN guidance and practice

  • The MAN ES filtration handbook is the general rule for oil cleanliness on ME-B and ME-C engines. I don't have its document number.
  • MAN accepts checking oil samples under a microscope.
  • When the sample is very dark (dark brown or black), you cannot see the particles well, so the oil needs filtering before the check.
  • But that filter holds back part of the particles, so the count you get is changed by this step.

What this note doesn't cover

  • Target cleanliness codes, particle size groups and filter fineness in microns.
  • Hydraulic oil requirements, sampling points and sampling intervals.
  • MAN service letter numbers, or any real fault case.

For these values, check the MAN ES filtration handbook and the engine documentation.